OUTDOOR COMBINATION SENSOR FOR HUMIDITY AND TEMPERATURE – ARFT/M – M12 Connection

Device for measuring humidity and temperature in outdoor areas or indoor areas subject to high requirements. The measuring transducer records the temperature and humidity via an internal sensor and coverts the value into a standardized analogue output signal in the range between 0-10V/4-20 mA. The sensor features long-term stability and no recalibration is required.

Meteorological house – WHT

Weather shelter is used in technique for automation and knowledge in them, namely, with the purpose of the use of active control units, depending on the temperature and humidity measurement. Thanks to a standardized output signal 0-10V or 4-20mA weather shelter can be connected to the existing systems of control and regulation.

Leakage sensor – LGM

LGM leakage sensor reliably defines conductive liquids and thus is ideal for tracking leak and humidity of materials. First of all the sensor finds the application in technique for buildings and ventilation.  By means of integrated output positional organs can be activated or deactivated. Optionally, it is possible to connect an acoustic or optical signal transmitter. The sensitivity is adjusted via a potentiometer during configuration of the switching polarity and an optional signal output via DIP-switch.

RAIN SENSOR – RGM

Device for detecting precipitation as either rain or snow. The circuit polarity and sensitivity are adjustable. A connectible heating prevents the formation of ice or dew and helps the device to dry faster.

RAUMHYGROSTAT MIT INNEN ODER AUSSENEINSTELLUNG – RHY

Der Raumhygrostat Hygroswitch ist ein Zweipunktregler zur Regelung der relativen Luftfeuchtigkeit. Unser Raumhygrostat kann eingesetzt werden zur Regelung der Luftbe- und entfeuchtung in Büro und Computerräumen.

Mehrere Einsatzgebiete

Weitere Einsatzgebiete des Raumhygrostat sind:

  • Lagerhaltung für Lebens- und Genussmittel
  • Kühlräume für Obst und Gemüse
  • Treibhäuser der Gartenbaubetriebe
  • Textilindustrie, Papier- und Druckindustrie, Filmindustrie, Krankenhäuser

Beim Raumhygrostat Hygroswitch-i befindet sich an Stelle des außenliegenden Drehknopfes im Inneren des Gehäuses ein Einstellrad mit Skala. Das Einstellrad des Raumhygrostat ist nach der roten Markierung auszurichten.

DUCT HYGROSTAT WITH INTERNAL AND EXTERNAL CONTROLS – KHY

The HG80 Hygrostat is a two-level controller for controlling the relative humidity in air ducts of air-conditioning system, conditioning cabinets. The device is also applied in food storages, cooling chambers for fruits and vegatables, greenhouses of gardening companies, textile industry, paper and printing industry, movie industry and hospitals – basically in all places where humidity monitoring and control is required.

CONDENSATION MONITOR – KDW2 AND KDW2/EXT

Our KDW2 and KDW2EXT condensation monitors are typically mounted to cooling and cold water pipes, cooling ceilings or other cooled surfaces. Both models offer reliable detection of condensation and protect the objects against the former. The KDW2Ext has an external measuring point and can easily be mounted in confined spaces. Our KDWs can be used as monitors on cooling ceilings and pipes and the additional internal switching output is capable of activating heatings or other actuators.

HIGH TEMPERATURE/HUMIDITY SENSOR – ARFT/R-X/HT

Device for measuring the relative humidity/temperature in outdoor areas or indoor areas subject to high requirements. The measuring transducer measures the temperature and humidity via an internal sensor and coverts the value into a standardized analogue output signal in the range between 0-10V/4-20 mA. Additionally, a passive temperature sensor can be connected. Various measuring ranges are available depending on the model. The sensor features long-term stability and no recalibration is required.

DEW POINT MONITOR -TPW / TPWEXT

The Dew Point Monitor measures the relative humidity on pipes, cooling ceilings or other surfaces and transfers the value as a linear analogue 4…20 mA output signal. The device also features a changeover contact for which the limiting value can be adjusted between 75 and 100 % r.h. with the help of a potentiometer. This way the respective signal can be transferred to the control/DDC when condensation is forming in order to activate the respective actuators.

DUCT COMBINATION SENSOR FOR HUMIDITY AND TEMPERATURE – KFFT/R-X/S

Device for measuring the relative humidity/temperature in ducts or indoor areas subject to high requirements. The measuring transducer records the temperature and humidity via an internal sensor and coverts the value into a standardized analogue output signal in the range between 0-10V/4-20 mA.

OUTDOOR COMBINATION SENSOR FOR RELATIVE HUMIDITY/TEMPERATURE – ARFT/R-X/S

Device for measuring the relative humidity/temperature in outdoor areas or indoor areas subject to high requirements. The measuring transducer records the temperature and humidity via an internal sensor and coverts the value into a standardized analogue output signal in the range between 0-10V/4-20 mA. Additionally, a passive temperature sensor can be connected. The sensor features long-term stability and no recalibration is required.